HS-P2200X

Expansion Inverter Module

Start with the application.

The HS-P2200X is the parallel expansion companion to the HS-P2200. When the 2200W output of a single unit is insufficient to drive multiple high-power devices at once, pairing the P2200X with the P2200 host raises the system AC output to 4400W without replacing or carrying a heavier main unit. The module shares the same BMS communication protocol and thermal management logic, with plug-and-play auto-detection; after parallel connection, load distribution, protection settings and SOC display are managed uniformly by the master-slave system. At 5kg with a low-profile horizontal form factor, it fits alongside the host for storage or mounting on a small rack. For users needing temporary expansion without sacrificing portability, the P2200X delivers doubled power margin at minimal marginal cost.

Technical information

ParameterValue
Function
TypeParallel expansion inverter module
Compatible HostHS-P2200
Total System Output After Parallel4400 W (2 units in parallel)
Max. Parallel Units2 (1 host + 1 expansion)
AC Output
Rated Output per Module2200 W
Total Parallel Output4400 W (continuous), peak 6000 W (<3 s)
Output Voltage / Frequency220-240 Vac / 50 Hz, synchronized with host
WaveformPure sine wave, THD <3%
AC Outlets4× Schuko (European standard)
Parallel Current Sharing Deviation<5%
Communication & Control
Master-Slave CommunicationCAN bus, auto-detection and current sharing
Protection LinkageSynchronized with host BMS / inverter protection settings
Cooperative Firmware UpgradeSupported (via host OTA)
Efficiency
Inverter Peak Efficiency93.5%
Parallel System Overall Efficiency92.8%
Standby Consumption (Slave)<3 W
Environment
Operating Temperature-10 to +45°C
Protection RatingIP21
CoolingSmart air cooling
Mechanical
Dimensions (L×W×H)465×300×103 mm
Weight5 kg
InstallationHorizontal placement / stacking with host
Certification
Safety & EMCFCC · ICES · EN 55032 · EN 62368-1
Warranty2 years

Let’s shape your next energy step.

Share your questions or project needs with the HESEN team.

Request consultation
Request consultation